Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthodont ; 28(1): e82-e88, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29484776

RESUMO

PURPOSE: To evaluate the effects of three fresh detox juices, including an orange, green, and red beverage, on the color stability and surface roughness of three anterior esthetic resin-based composites (RBCs). MATERIALS AND METHODS: Disk-shaped specimens were prepared with three different esthetic RBCs (Amaris, G-aenial Anterior, Clearfil Majesty ES-2) according to the manufacturers' instructions. Forty specimens were prepared for each RBC, and all specimens were stored in artificial saliva at 37°C for 24 hours. The initial color values and surface roughness measurements of the specimens were taken using a spectrophotometer and a profilometer. The specimens were then divided into 4 subgroups (n = 10). All specimens except the control specimens were immersed in their designated fresh detox juices (green, red, or orange) for 10 minutes twice a day. Color and surface roughness measurements were taken on day 15 and day 30, and the results were analyzed by one-way ANOVA and Tukey HSD test. The association between color change and surface roughness was evaluated by Spearman's Rank Correlation analysis. RESULTS: Color changes and surface roughness increased upon exposure to fresh detox juices for 15 and 30 days for all of the RBCs. All of the G-aenial and Amaris groups displayed color changes above the threshold of acceptability, whereas Clearfil Majesty ES-2 displayed a color change above the threshold of acceptability only after exposure to the red beverage for 30 days (ΔE > 3.7). With regard to surface roughness, Clearfil Majesty ES-2 outperformed the other RBCs (p < 0.001). According to Spearman's Rank Correlation analysis, there was no correlation between color change and surface roughness (p > 0.001). CONCLUSIONS: Exposure to the fresh detox juices used in this study led to similar color changes in the RBCs used in this study.


Assuntos
Bebidas/efeitos adversos , Resinas Compostas/química , Cor , Restauração Dentária Permanente/métodos , Estética Dentária , Humanos , Espectrofotometria , Propriedades de Superfície
2.
J Prosthodont ; 28(1): e222-e228, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28872730

RESUMO

PURPOSE: To evaluate microleakage in roots restored with fiber posts cemented using three different luting cements, to measure the volume of voids/gaps within the obturated/postcemented root canals, and to examine whether microleakage and the volume of voids/gaps were correlated. MATERIALS AND METHODS: Thirty-six extracted human mandibular incisors were decoronated, and the root canals were obturated using gutta-percha and sealer in the experimental groups (n = 30). Six roots were used as controls. A standard post space was prepared, and an identically sized fiber post was cemented in each experimental specimen using one of three luting cements (Panavia F2.0, Bifix SE, GC FujiCEM; n = 10 each). The specimens were scanned using micro-computed tomography, and the volume of voids/gaps was determined. The specimens were then subjected to a fluid filtration assay to evaluate microleakage. RESULTS: The volume of voids/gaps was significantly lower in the GC FujiCEM group, and significantly less microleakage occurred in the Bifix SE group compared with other groups (both p < 0.001). A significant correlation between the volume of voids/gaps and leakage was found only in the Panavia F2.0 group (p = 0.003; r = 0.830). No such correlation was found in the analysis of all groups combined. CONCLUSIONS: The group with the greatest volume of voids/gaps (Bifix SE) showed the least microleakage, and the group with the smallest volume of voids/gaps (GC FujiCEM) showed the most microleakage. Panavia F2.0 ranked between and exhibited significant correlation.


Assuntos
Cimentação/métodos , Cimentos Dentários/química , Infiltração Dentária , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular/química , Colagem Dentária , Infiltração Dentária/prevenção & controle , Materiais Dentários/química , Cavidade Pulpar/diagnóstico por imagem , Adesivos Dentinários/química , Vidro , Cimentos de Ionômeros de Vidro/química , Guta-Percha , Humanos , Hidroxibenzoatos , Incisivo , Teste de Materiais , Nitrofuranos , Cimentos de Resina , Obturação do Canal Radicular , Tratamento do Canal Radicular/métodos , Microtomografia por Raio-X
3.
Appl Bionics Biomech ; 2018: 8916928, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29736185

RESUMO

OBJECTIVE: The purpose of this study was to test different restoration combinations used for constructing fractured endodontically treated incisors by reattaching their fractured fragments. METHODS: Seven types of 3-D FEM mathematical root canal-filled models were generated, simulating cases of (OB) reattaching fractured fragments; (CrPL) reattaching fractured fragments + ceramic palatinal laminate; (CmPL) reattaching fractured fragments + composite palatinal laminate; (CM) reattaching fractured fragments + coronal 1/3 of the root was filled using core material; (BP) reattaching fractured fragments + glass fiber post; (CP) composite resin restoration + glass fiber post; and (OC) composite resin restoration. A 100-N static oblique force was applied to the simulated teeth with 135° on the node at 2 mm above the cingulum to analyze the stress distribution at the tooth. RESULTS: For enamel tissue, the highest stress values were observed in model BP, and the lowest stress values were observed in model CmPL. For dentine tissue, the highest stress concentrations were observed around the fracture line for all models. CONCLUSIONS: Reattachment of fractured fragments by bonding may be preferred as a restoration option for endodontically treated incisors; also, palatinal laminate decreases the stress values at tooth tissues, especially at the enamel and the fracture line.

4.
Photomed Laser Surg ; 36(4): 191-197, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29261013

RESUMO

OBJECTIVE: The aim of this in vitro study was to evaluate the diagnostic performance of visual inspection (VI), laser fluorescence (LF pen), fluorescence camera (FC), and alternating current impedance spectroscopy technique (ACIST) for detection of incipient occlusal caries lesions. Histology was used as the gold standard to determine the interexaminer reliability of the methods, among three examiners with different levels of experiences (Examiner 1: 5 years; examiner 2: 10 years; and examiner 3: 25 years). MATERIALS AND METHODS: One hundred two molar teeth were selected. The occlusal surfaces of teeth were evaluated with VI, LF pen, FC, and ACIST devices independently by three examiners. Diagnostic performances of methods were evaluated with binormal receiver-operating characteristics analysis. Interexaminer agreement of detection methods was assessed using Cohen's kappa coefficient values (p < 0.001). RESULTS: Incipient enamel lesions were determined more successfully with VI by all examiners. All detection methods were presented with statistically acceptable interexaminer agreement (p < 0.001). For D2 and D3 thresholds, FC for examiner 1, VI for examiner 2, and both VI and FC for examiner 3 demonstrated statistically high sensitivity and specificity (p < 0.05). CONCLUSIONS: It can be concluded that diagnostic performance of the methods was insufficient for detecting incipient occlusal caries lesions by itself. Performance can be improved by using them with VI as a traditional caries detection method.


Assuntos
Cárie Dentária/diagnóstico , Fluorescência , Lasers , Análise Espectral , Humanos , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Técnicas de Cultura de Tecidos
5.
J Clin Exp Dent ; 9(3): e460-e465, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28298992

RESUMO

BACKGROUND: The aim of this study was to evaluate effects of different polishing methods and whitening agents on surface hardness and roughness of nano-hybrid composite resin. MATERIAL AND METHODS: In total, one hundred twenty disc-shaped specimens were prepared to nano-hybrid composite (Charisma Diamond). 60 samples were used for microhardness measurements and the others were used for the evaluation of surface roughness. Samples were divided randomly into two subgroups (n = 30 each). In first group a low-viscosity liquid polishing agent (Biscover LV) was applied. In the second group, nothing was applied. All the samples were stored in distilled water at 37°C for 24 h. After initial measurements were completed, samples were divided randomly into three subgroups for bleaching application. 10% carbamide peroxide (Opalescence PF), 45% carbamide peroxide (Opalescence PF Quick), 38% hydrogen peroxide (Opalescence Boost) was applied. Then microhardness and surface roughness measurements of samples were repeated and data were recorded as final values for each sample. RESULTS: When the polishing techniques were compared, no signicant difference was observed in surface hardness and roughness. When the bleaching agents were compared, the 10% carbamide peroxide and 38% hydrogen peroxide containing bleaching agent groups showed statistically significant differences between pre- and post-procedure hardness values (p<0.05). CONCLUSIONS: Office-type bleaching agent containing CP was observed to be more secure for composite resins than other bleaching agents. No negative effect of glaze materials on the protection of surface roughness and hardness of composite resin was observed. Key words:Composite resin, bleaching, surface hardness, surface roughness.

6.
Appl Bionics Biomech ; 2017: 9124545, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29440865

RESUMO

The purpose of this study was to evaluate the effects of different palatal applications on fracture strength of the fractured anterior tooth. Sixty caries-free human maxillary incisors were used. Endodontic treatments of the teeth were performed. Then, the teeth were divided randomly into five groups (n = 12). Crowns of all teeth in groups A-D were cut with diamond discs at a fixed distance of 3 mm from the incisal margin in a plane normal to the buccal surface. In all groups, coronal fragments were reattached to the remaining teeth by bonding with hybrid composite resin. After then, the teeth were restored to the following; group A, bonding and palatal laminate; group B, bonding and creation of a vertical groove; group C, bonding and creation of two slot grooves; group D, bonding only; and group E, intact tooth. It was lesser in group B than in groups C and E (p = 0.007 and p = 0.006, resp.) and lesser in group D than in groups A, C, and E (p = 0.002, p < 0.001, and p < 0.001, resp.). Within the limitations of this in vitro study, it can be concluded that methods employing palatinal laminate and small grooves are clinically feasible for the reattachment of tooth fragments to incisors.

7.
J Clin Exp Dent ; 8(1): e55-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26855707

RESUMO

BACKGROUND: The aim of this study was to evaluate the effect of a desensitizing agent on microleakage of Class V cavities. MATERIAL AND METHODS: 72 premolar teeth were used. There were 6 groups. Class V restorations were prepared with two different restorative materials (Equia fil, GC, America and Grandio, VOCO, Germany) and two adhesive systems (Clearfil SE Bond, Kuraray, Japan and S3 Bond Plus, Kuraray, Japan) with and without desensitizing agent (Gluma Desensitizer, Heraeus Kulzer, Germany). Restorations were polished with aluminum oxide abrasive discs. Then a range of 5 - 55C thermocycling was performed 10.000 times. The microleakage of restorations was examined with dye penetration method (Basic fuchsine). Bonferroni corrections and Kruskal-Wallis test were used to determine the significance of differences in occlusal and gingival dye penetration scores between groups. RESULTS: There was no stastistical significance between the occlusal and gingival microleakage scores within the groups were shown. CONCLUSIONS: It can be concluded that use of desensitizing agent under both high viscosity glass ionomer restorative materials and resin composites doesn't affect the microleakage. KEY WORDS: High viscosity glass ionomer cement, composite resin, desensitizing agent, microleakage.

8.
ScientificWorldJournal ; 2013: 426134, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23956694

RESUMO

The aim of this study was to analyze the stresses that develop by oblique and vertical forces in endodontically treated maxillary second premolars that were restored with resin composite. Additionally, in our study the effects of the different restorative approaches and use of different base materials on stress formation were analyzed using three-dimensional finite element stress analysis. For restoration, the models representing both cusp capping, palatinal cusp capping, standard MOD restoration, and use of woven fiber in occlusal part were prepared. In all models, oblique forces caused more stress than did vertical forces. Materials with low elastic moduli cause high amounts of stress, whereas materials with elastic moduli similar to that of dental tissues cause low amounts of stress. Additional approaches such as cusp capping, functional cusp capping, and woven fiber use do not affect stress formation on the tooth after endodontic treatment.


Assuntos
Análise de Elementos Finitos , Estresse Mecânico , Dente não Vital , Humanos
9.
Eur J Dent ; 7(Suppl 1): S020-S025, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24966724

RESUMO

OBJECTIVE: The aim of this study was to evaluate the change in surface hardness of silorane-based composite resin (Filtek Silorane) in time and compare the results with the surface hardness of two methacrylate-based resins (Filtek Supreme and Majesty Posterior). MATERIALS AND METHODS: From each composite material, 18 wheel-shaped samples (5-mm diameter and 2-mm depth) were prepared. Top and bottom surface hardness of these samples was measured using a Vicker's hardness tester. The samples were then stored at 37°C and 100% humidity. After 24 h and 7, 30 and 90 days, the top and bottom surface hardness of the samples was measured. In each measurement, the rate between the hardness of the top and bottom surfaces were recorded as the hardness rate. Statistical analysis was performed by one-way analysis of variance, multiple comparisons by Tukey's test and binary comparisons by t-test with a significance level of P = 0.05. RESULTS: The highest hardness values were obtained from each two surfaces of Majesty Posterior and the lowest from Filtek Silorane. Both the top and bottom surface hardness of the methacrylate based composite resins was high and there was a statistically significant difference between the top and bottom hardness values of only the silorane-based composite, Filtek Silorane (P < 0.05). The lowest was obtained with Filtek Silorane. The hardness values of all test groups increased after 24 h (P < 0.05). CONCLUSION: Although silorane-based composite resin Filtek Silorane showed adequate hardness ratio, the use of incremental technic during application is more important than methacrylate based composites.

10.
Eur J Dent ; 6(1): 79-86, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22229011

RESUMO

OBJECTIVES: The aim of this study was to evaluate surface roughness and hardness of a nanofiller GIC, a resin-modified GIC, three conventional GICs, and a silver-reinforced GIC. METHODS: For each material, 11 spcecimens were prepared and then stored in distilled water at 37 °C for 24 h. The surface roughness of 5 specimens was measured using a surface profilometer before polishing and after polishing with coarse, medium, fine, superfine aluminum oxide abrasive Sof-Lex discs respectively. The hardness of the upper surfaces of the remaining 6 specimens was measured with a Vickers microhardness measuring instrument. RESULTS: All tested GICs showed lower surface roughness values after the polishing procedure. Surface finish of nanofiller GIC was smoother than the other tested GICs after polishing. This was followed by resin-modified GIC, Fuji II LC; then silver-reinforced GIC, Argion Molar, conventional GICs, Aqua Ionofil Plus, Fuji IX, and Ionofil Molar, respectively. The result of the hardness test indicated that the microhardness value of silver-reinforced GIC was greater than that of the other GICs. When the hardness values of all tested GICs were compared, the differences between materials (except Aqua Ionofil Plus with Ionofil Molar and Ketac N100 with Fuji II LC (P>.05)) were found statistically significant (P<.05). CONCLUSIONS: According to the results of this study, it can be concluded that the differences in the composition of GICs may affect their surface roughness and hardness.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...